3. I/O Control Instruction
I/O terminal connector – used in application, for e.g., motion detection, event triggering, alarm
notifications. It provides the interface to:
Digital Input (GND+Alarm) : An alarm input for connecting devices that can toggle between
an open and closed circuit, for
1. GND (Ground) : Initial state is LOW
2. Alarm : Max. 50mA, DC 5V
Example: PIRs, door/window contacts, glass break detectors, etc. When a signal is
received the state changes and the input becomes active.
2.3 Factory Default
1. Remove the Ethernet cable and power adapter.
2. Take an electronic wire, plug one side of the wire into “Default” and the other side into “GND” on
the terminal block as the photo below.
3. Connect power again and connect Ethernet cable after the camera finishes rebooting..
4. Remove the wire. When camera starts again, please remove the pink default cable and plug
Ethernet cable for new setting.
5. Release the button when camera finishes proceed.
6. Re-login the camera using the default IP (http://192.168.1.200) or DHCP, and user name (admin),
password (admin).
.